Infrared Thermal Imaging Camera's and CCTVs
Radio Frequency (RF) Jammers and VIP Convoy Protectors
Amplifiers, Signal Conditioners and Fiber Optic Links
Sputtering and Plasma Systems
Speed Displays, Surface Flow Velocity, Railroad Radars and Safety Packages
Search and Tactical Lights
|
|
|
|
|
|
|
GAGE-3001 General Purpose Transducer Interface Board
|
|
|
|
Introduction
|
|
The GAGE-3001 is a miniature interface board, used for interfacing any bridge-type type transducer such as Strain Gage, Pressure Sensor and other bridge-type transducers, as well as voltage producing devices such as Piezo Sensors, Temperature Sensors, Photo Diodes and EEG/ECG inputs.
|
|
The GAGE-3001 provides a variable excitation, capable of deriving up to 80 mA, at voltage range of 1V to 20V. The excitation voltage is symmetrical about ground level, so that the common mode voltage is approx. 0V. For example: an excitation voltage of 12V will be ±6V relative to ground.
|
|
The GAGE-3001 also contains an Instrumentation Amplifier, with a variable gain of 150-1500, and a variable offset control. The output of the Instrumentation Amplifier is fed to a double pole Low-Pass-Filter, then passed via a driver buffer to the output port. The cut-off frequency of the Low-Pass-Filter may be changed by replacing two capacitors, CX1 and CX2, with capacitors of other values. The following Table provides capacitors values for some often used cut-off frequencies:
|
Cut-Off Freq. |
50 Hz |
100 Hz |
200 Hz |
500 Hz |
1 kHz |
2 kHz |
5 kHz |
10 kHz |
20 kHz |
Capacitor Value CX1/CX2 |
330 nF |
150 nF |
80 nF |
33 nF |
15 nF |
8 nF |
3.3 nF |
1.5 nF |
1 nF |
|
|
The GAGE-3001 also has a bridge loading resistor Rx, connected in series with a variable trimpot (variable resistor) designated P2. The resistor is used for correcting the offset of a bridge, which has a high offset level that cannot be corrected by using the on-board offset control. This resistor has to be defined and connected by the user. Please note that this resistor may adversely affect the linearity of the bridge, therefore it is recommended to correct the high offset by fixing the transducer.
|
|
The excitation of the GAGE-3001 may be changed by using a trimpot designated P6, while the excitation level may be measured between the -EXC and +EXC test points. The gain is adjusted using P1.
|
|
The GAGE-3001 requires an external stabilized power supply of ±8V to ±15V. An optional battery power supply can also be supplied.
|
|
The GAGE-3001 is pin compatible with the Gage-3001 interface card in all inputs, outputs and power supply lines.
|
|
The GAGE-3001 has wider bandwidth, lower noise and lower drift than the GAGE-3001.
|
|
Figure I Block Diagram:
|
|
Features:
|
For use with any bridge-type transducers, pressure gages, strain gages, etc.
High gain - 1500 standard,up to 10000 optional
Ultra high input impedance - 1 GW
High frequency response - up to 50kHz
Built-in user-programmable Low Pass Filter
Built-in excitation
High common-mode rejection - 120dB min.
Low noise, low offset and drift
Low cost
|
|
Applications:
|
Weighing systems
Interfacing of load cells to A/D cards
Amplification of low-level sensors (Pressure Transducers, Light-sensing Devices, Thermistors, etc.)
Medical applications: EEG, ECG, etc
|
|
Technical Specifications:
|
|
PARAMETER
|
VALUE
|
|
Gain
|
100-1500 (adjustable by user) up to 10,000-optional
|
|
Gain Non-Linearity
|
± 0.006%
|
|
Gain Temp. Coef.
|
30 ppm/C°
|
|
Input Offset Drift
|
1 µV/C°
|
|
Output Offset Drift
|
100 µV/C°
|
|
Input Offset Vs. Supply
|
85 dB
|
|
Input Impedance
|
2G
|
|
Drift. Capacitance
|
5 pF
|
|
CMRR ( DC - 100 Hz )
|
120 dB
|
|
Bandwidth ( Gain 100 - 1000 )
|
50 kHz min. (-3 dB)
|
|
Setting time to 0.01%
|
30 µ Sec. (no filter installed)
|
|
Input Noise Voltage (@ 1 kHz)
|
10 nV/
|
|
Output Noise
|
100 nV/
|
|
Supply Voltage Range
|
±8V to ±15V
|
|
Excitation Level
|
±1V to ±10V
|
|
Excitation Current (max.)
|
80 mA
|
|
Excitation Drift
|
5 ppm/C° ±10 µV/C°
|
|
Excitation Noise (DC - 100 kHz)
|
0.6 mV max (@300R load)
|
|
Excitation Noise (DC - 1 kHz)
|
0.2 mV max (@300R load)
|
|
Operating Temperature
|
0 - 70 C°
|
|
Bridge Resistance Range
|
50 - 20,000
|
|
Clarification(s) may be sought at info@globesolutionz.com
|
|